微量氧變送器TELEDYNE 型號(hào)XC13-Insta Trans-XD庫(kù)號(hào)D179081
庫(kù)號(hào):D179081
DESCRIPTION
Two-Wire Loop-Powered Oxygen Transmitter
SPECIFICATIONS
? Single user-settable range, 0-10 ppm to 0-25% Oxygen
? Front-facing head containing digital display and keys for convenient wall mounting
? Accepts most Teledyne industrial sensors
(Insta-trace and A-5 type cells require special configurations)
? Weather-tight housing designed to meet NEMA-4 / IP-66 ingress
protection requirements
? 316SS cell housing with 316SS 1/8" tube fittings and Viton® o-ring as standard
? Optional fittings: 1/4" tube, 6mm tube, no fitting (1/8" FNPT threads)
? Optional o-rings of Kalrez®, EPDM, EPR, Neoprene, Chemraz® and Buna-n
? Microprocessor-
? 4.5 digit LCD
? 4-20mA loop output
? Cold boot and 4-20 fine adjust features included as standard
? Intrinsically safe to ATEX Ex ia IIC T4 Ga when wired with approved barrier as per D86181 Interconnection Diagram
? Intrinsically safe to FM / FMc Class I Div 1 Gp A-D T4 when wired with approved barrier as per
D I8n6te1r8c1onnection Diagram and FM / FMc Class I Div 2 Gp A-D T4 without barrier (approvals pending)
? Cable included, 2-conductor 22 AWG shielded, 24 inch (610 mm) length
? Fuel cell included
DESCRIPTION
Two-Wire Loop-Powered Oxygen Transmitter
SPECIFICATIONS
? Single user-settable range, 0-10 ppm to 0-25% Oxygen
? Front-facing head containing digital display and keys for convenient wall mounting
? Accepts most Teledyne industrial sensors
(Insta-trace and A-5 type cells require special configurations)
? Weather-tight housing designed to meet NEMA-4 / IP-66 ingress
protection requirements
? 316SS cell housing with 316SS 1/8" tube fittings and Viton® o-ring as standard
? Optional fittings: 1/4" tube, 6mm tube, no fitting (1/8" FNPT threads)
? Optional o-rings of Kalrez®, EPDM, EPR, Neoprene, Chemraz® and Buna-n
? Microprocessor-
? 4.5 digit LCD
? 4-20mA loop output
? Cold boot and 4-20 fine adjust features included as standard
? Intrinsically safe to ATEX Ex ia IIC T4 Ga when wired with approved barrier as per D86181 Interconnection Diagram
? Intrinsically safe to FM / FMc Class I Div 1 Gp A-D T4 when wired with approved barrier as per
D I8n6te1r8c1onnection Diagram and FM / FMc Class I Div 2 Gp A-D T4 without barrier (approvals pending)
? Cable included, 2-conductor 22 AWG shielded, 24 inch (610 mm) length
? Fuel cell included